Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38608191

RESUMEN

OBJECTIVE: To compare digital panoramic radiography (DPR) and cone beam computed tomography (CBCT) in the detection and classification of pulp calcifications in posterior teeth in relation to tooth condition and its location. METHODS: 250 patients with simultaneous DPR and CBCT scans were selected from a dental image bank. For each posterior tooth, its condition was registered (healthy, restored, or decayed). The presence of calcifications was assessed and classified according to location (coronal or radicular) and type (total obliteration, partial obliteration, narrowing, and no calcification). Chi-square and McNemar tests were used to compare DPR and CBCT results, with a significance level of 5%. DPR diagnostic values were calculated using CBCT as reference. RESULTS: Decayed and restored teeth showed a significantly (p < 0.001) higher prevalence of pulp calcifications than healthy teeth in both imaging exams. There was a significant discrepancy between the imaging modalities in the identification of calcifications (p < 0.001), especially for radicular calcifications of maxillary teeth (DPR = 55.2%; CBCT = 30.9%). In the case of coronal calcifications, there was a greater discrepancy between CBCT and DPR in the mandibular teeth (10.7%) than in the maxillary teeth (7.7%). Overall, DPR presents higher sensitivity (0.855) than specificity (0.483) for pulp calcifications detection. CONCLUSION: DPR considerably overestimates pulp calcifications in posterior teeth, as compared to CBCT. A higher prevalence of pulp calcifications is related to decayed and restored teeth.

2.
J Dent ; 144: 104963, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38522636

RESUMEN

OBJECTIVE: To investigate the association of perforation of the maxillary sinus floor by dental implants with mucosal thickening and to describe its characteristics in perforated cases. STUDY DESIGN: One-hundred and twenty-nine maxillary sinuses of 93 patients presenting 202 dental implants in the maxillary posterior region were retrospectively assessed in cone-beam computed tomography scans and classified according to maxillary sinus perforation, bone graft, mucosal thickening, and mucosal appearance. Logistic regression determined the chance of mucosal thickening in perforated maxillary sinuses. The chi-square test compared categorical variables between maxillary sinus perforated or not by implants and maxillary sinus with or without mucosal thickening. The significance level assumed was 5 % (α = 0.05). RESULTS: There was perforation of 60 maxillary sinuses floor (46.5 %) by 74 dental implants. The chance of mucosal thickening was higher when the implant tip was trespassing on the maxillary sinus floor (p < 0.001). There was a significant association between maxillary sinus mucosal thickening and perforation by a dental implant with the tip trespassing the maxillary sinus floor (p < 0.05). CONCLUSION: Maxillary sinus mucosal thickening is associated with sinus floor perforation by dental implants and does not depend on the number of implants perforating it. CLINICAL RELEVANCE: There is an association between dental implants' perforation of the maxillary sinus floor and the thickening of the maxillary sinus. In those cases, the appearance of the mucosa thickening may be irregular, local, or total opacification of the sinus cavity.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Implantes Dentales , Seno Maxilar , Humanos , Seno Maxilar/diagnóstico por imagen , Seno Maxilar/patología , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Implantes Dentales/efectos adversos , Anciano , Adulto , Mucosa Nasal/diagnóstico por imagen , Mucosa Nasal/lesiones , Mucosa Nasal/patología , Trasplante Óseo , Anciano de 80 o más Años
3.
Dentomaxillofac Radiol ; 53(4): 233-239, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38466923

RESUMEN

OBJECTIVES: This study evaluated the effect of metal artefact reduction (MAR) level and tube current on the assessment of dental implant positioning relative to the mandibular canal (MC) through cone-beam computed tomography (CBCT). METHODS: Titanium dental implants were placed in dried mandibles at 0.5-mm superior to the MC (group 1/n = 8) and 0.5-mm inside the MC with perforation of the cortex (group 2/n = 10). CBCT scans were obtained with different levels of MAR (off, medium, and high) and 2 tube currents (4 and 8 mA). Four examiners analysed the images and scored the contact between the implant and the MC using a 5-point scale. Sensitivity, specificity, area under receiver operating characteristic curve (ROC), and frequency of scores were calculated. Data were compared with analysis of variance 2-way and Tukey's test and scores with Chi-square test. RESULTS: Specificity and area under ROC curve decreased significantly when MAR level was high compared with MAR-medium and MAR-off. The frequency of score 3 (inconclusive) was the highest, and scores 1 and 5 (definitely no contact and definitely contact, respectively) were the lowest with MAR-high, regardless of the tube current. When MAR was off, there were higher frequencies of scores 1 and 5. CONCLUSIONS: The level of MAR influences the assessment of the relationship between the dental implant and the MC. MAR-high led to lower diagnostic accuracy compared with MAR-medium and off. ADVANCES IN KNOWLEDGE: This article shows that high level of MAR can interfere in the diagnostic of dental implant positioning relative to the MC, decreasing its accuracy.


Asunto(s)
Artefactos , Tomografía Computarizada de Haz Cónico , Implantes Dentales , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Mandíbula/diagnóstico por imagen , Titanio , Sensibilidad y Especificidad , Metales , Técnicas In Vitro
4.
Artículo en Inglés | MEDLINE | ID: mdl-38365543

RESUMEN

OBJECTIVE: To assess the accuracy and reproducibility of cephalometric landmark identification performed by 2 artificial intelligence (AI)-driven applications (CefBot and WebCeph) and human examiners. STUDY DESIGN: Lateral cephalometric radiographs of 10 skulls containing 0.5 mm lead spheres directly placed at 10 cephalometric landmarks were obtained as the reference standard. Ten radiographs without spheres were obtained from the same skulls for identification of cephalometric points performed by the AI applications and 10 examiners. The x- and y-coordinate values of the cephalometric points identified by the AI applications and examiners were compared with those from the reference standard images using one-way analysis of variance and the Dunnet post-hoc test. The intraclass correlation coefficient (ICC) was used to evaluate reproducibility. Mean radial error (MRE) in identification was calculated with respect to the reference standard. Statistical significance was established at P < .05. RESULTS: Landmark identification by CefBot and the examiners did not exhibit significant differences from the reference standard on either axis (P > .05). WebCeph produced a significant difference (P < .05) in 4 and 6 points on the x- and y-axes, respectively. Reproducibility was excellent for CefBot and the examiners (ICC ≥ 0.9943) and good for WebCeph (ICC ≥ 0.7868). MREs of CefBot and the examiners were similar. CONCLUSION: With results similar to those of human examiners, CefBot demonstrated excellent reliability and can aid in cephalometric applications. WebCeph produced significant errors.


Asunto(s)
Inteligencia Artificial , Cráneo , Humanos , Reproducibilidad de los Resultados , Cefalometría/métodos , Radiografía
5.
J Oral Rehabil ; 51(3): 517-525, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37941125

RESUMEN

BACKGROUND: There is no established protocol for the low doses of cone-beam computed tomography (CBCT) acquisition and filter application on the diagnosis of condylar morphological alterations. OBJECTIVES: The objective of the study was to evaluate the influence of voxel size and filter application on the diagnosis of condylar morphological alterations in CBCT using an ex vivo model. METHODS: CBCT scans of 36 temporomandibular joints were acquired using OP300 Maxio with voxel sizes of 0.085, 0.125 and 0.280 mm. Three radiologists evaluated the condyles in the CBCT volumes under three filter modes: no filter, '1x' sharpen filter and '2x' sharpen filter. The area under the ROC curve, sensitivity and specificity were calculated by comparing the evaluators' responses with the reference standard and compared among experimental groups using analysis of variance (ANOVA) (α = 5%). RESULTS: The area under the ROC curve, sensitivity and specificity were not affected by voxel size and filter application (p > .05). For osteophyte and flattening, there were more true-positive responses in smaller voxel size. For erosion, the increase of true- and false-positive responses occurred with a larger voxel size. Overall, there was a tendency to decrease true positives for osteophyte and erosion and increase false positives for flattening with the '2x' sharpen filter. CONCLUSIONS: The diagnosis of condylar morphological alterations assessed in this ex vivo analysis is not influenced by the voxel size and the application of the filters. However, attention is needed with the occurrence of false-positive diagnosis with a larger voxel size for erosion and '2x' sharpen filter for flattening.


Asunto(s)
Osteofito , Tomografía Computarizada de Haz Cónico Espiral , Humanos , Sensibilidad y Especificidad , Tomografía Computarizada de Haz Cónico/métodos , Huesos
6.
Oral Radiol ; 40(1): 30-36, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37540349

RESUMEN

OBJECTIVE: To investigate whether the curve markings performed prior to panoramic and cross-sectional reconstructions can influence the planning of oral implants. METHODS: Twenty oral radiologists landmarked the reference panoramic curves in 25 CBCT scans of the mandible. Bone height was measured on the resulting cross-sectional slices in the edentulous region of the lower first molar. The following data were recorded: (1) number of landmarks used to build each reference curve; (2) shape of the reference curve (inverted "U", inverted "V" or "horseshoe"); and (3) measurement in the first molar region. The data were assessed for variability based on the number of landmarks, the shape of the reference curve, and the measurements obtained. RESULTS: The number of landmarks used to guide the panoramic reconstruction varied among radiologists (p < 0.05), but most of them draw curves in inverted "U" shape (68-100%). The reproducibility of the measurements taken in the edentulous mandibular first molar region was excellent (84.7%). The number of landmarks and the shape of the curve did not have a significant influence on the reproducibility of the measurements (p > 0.05). CONCLUSION: Variations of the operator-dependent steps during the panoramic reconstructions occur but do not play a significant part changing the measurements taken for oral implant planning.


Asunto(s)
Implantes Dentales , Tomografía Computarizada de Haz Cónico Espiral , Radiografía Panorámica , Tomografía Computarizada de Haz Cónico , Reproducibilidad de los Resultados , Estudios Transversales
7.
Microbiol Spectr ; 11(6): e0193423, 2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-37850787

RESUMEN

IMPORTANCE: One of the most important control points in gene regulation is RNA stability, which determines the half-life of a transcript from its transcription until its degradation. Bacteria have evolved a sophisticated multi-enzymatic complex, the RNA degradosome, which is dedicated mostly to RNA turnover. The combined activity of RNase E and the other RNA degradosome enzymes provides an efficient pipeline for the complete degradation of RNAs. The DEAD-box RNA helicases are very often found in RNA degradosomes from phylogenetically distant bacteria, confirming their importance in unwinding structured RNA for subsequent degradation. This work showed that the absence of the RNA helicase RhlB in the free-living Alphaproteobacterium Caulobacter crescentus causes important changes in gene expression and cell physiology. These are probably due, at least in part, to inefficient RNA processing by the RNA degradosome, particularly at low-temperature conditions.


Asunto(s)
Caulobacter , Caulobacter/genética , Caulobacter/metabolismo , Temperatura , ARN/metabolismo , ARN Helicasas DEAD-box/genética , ARN Helicasas DEAD-box/metabolismo , Procesamiento Postranscripcional del ARN
8.
Artículo en Inglés | MEDLINE | ID: mdl-37407350

RESUMEN

OBJECTIVE: The objective of this study was to evaluate the effects of spatial resolution and the application of enhancement filters in the diagnosis of simulated furcation defects and image quality with intraoral radiographs. STUDY DESIGN: Periapical images were acquired with photostimulable phosphor plates of molars in dry skulls (n = 8) and mandibles (n = 10) with 4 stages of furcation defect simulation. The plates were scanned in fast scan and high resolution modes to produce different spatial resolutions. Four image filters were applied. Six observers scored the detection of furcation defects. Mean values of area under the curve in receiver operating characteristic evaluation, accuracy, sensitivity, and specificity were calculated. Mean gray value (brightness), noise, and contrast-to-noise ratio (CNR) were calculated for enamel, dentin, and alveolar bone to evaluate image quality. Analysis of variance compared the values between the different spatial resolutions and filters. The significance of difference was established at P < .05. RESULTS: There were no significant differences in overall diagnostic values comparing image spatial resolutions and filters. Diagnostic outcomes were significantly better for the largest defects than the smallest lesions but were generally poor in detecting lesions. All structures showed greater brightness in high resolution. . Noise was greater in all structures with all enhancement filters except inversion. Dentin and alveolar bone exhibited more noise and lower CNR in high resolution. CONCLUSIONS: Varying spatial resolution and applying enhancement filters did not significantly affect the diagnosis of furcation defects.


Asunto(s)
Defectos de Furcación , Intensificación de Imagen Radiográfica , Humanos , Intensificación de Imagen Radiográfica/métodos , Defectos de Furcación/diagnóstico por imagen , Radiografía Dental Digital , Curva ROC , Mandíbula/diagnóstico por imagen
9.
Artículo en Inglés | MEDLINE | ID: mdl-37468379

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the influence of binarization methods (BnMs) on the fractal dimension (FD) of the alveolar bone in digital radiographic images. STUDY DESIGN: Five identical periapical radiographs were obtained from each of 20 anatomic regions. Using ImageJ/Fiji software, a standardized region of interest was positioned in the trabecular bone of all radiographs, 14 BnMs were independently applied, and FD was calculated. The Friedman test and Dunn post hoc tests were used to evaluate the influence of BnMs on FD (α = 0.05). The intraclass correlation coefficient (ICC) was used to assess correlation among BnMs. RESULTS: No significant differences were observed in the threshold value between the BnMs. No significant differences in FD were observed among 9 BnMs (Default, Huang, Iso Data, Li, Mean, Min Error[I], Moments, Otsu, and Shanbhag). These methods presented significantly higher FDs than those from 3 other BnMs (Max Entropy, Renyi Entropy, and Yen), which did not significantly differ from each other. The Triangle method significantly differed from all BnMs, and the Percentile method produced significantly higher FDs than Huang, IsoData, Li, Moments, Otsu, and Shanbhag. Most BnMs presented good or excellent correlation (ICC ≥ 0.76). CONCLUSIONS: Binarization methods influence FD of the alveolar bone from digital periapical radiographs; thus, this technical aspect is relevant for comparison purposes and should be standardized. For comparison of published FD research, the Default method is recommended.


Asunto(s)
Fractales , Mandíbula , Humanos , Radiografía Dental Digital/métodos , Radiografía , Hueso Esponjoso
10.
Odovtos (En linea) ; 25(1)abr. 2023.
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1422191

RESUMEN

The aim of this study was to observed the anesthetic efficacy of the alveolar nerve block on nine patients that CBCT diagnosed unilateral retromolar canal on a double-blind, split-mouth approach. The assessments of patient response to thermal (pulp vitality test) and pressure (compression of soft tissue) stimuli were carried out before and 5 minutes after the inferior alveolar nerve block procedure, using both visual analog scale (VAS) and Mc Gill pain questionnaires (McG). The mean percentage of patient response decreased after alveolar nerve block, according to both VAS and McG, and was statistically similar among hemi mandibles with and without retromolar canal (Wilcoxon>0.05); however, those without retromolar canal presented greater reduction in patient response in 6 out of 9 cases. Therefore, the retromolar canal is not a determinant factor of inferior alveolar nerve block failure.


El objetivo de este estudio fue observar la eficacia anestésica del bloqueo del nervio alveolar en nueve pacientes que CBCT diagnosticó canal retromolar unilateral en un abordaje de boca dividida doble ciego. Las evaluaciones de la respuesta del paciente a los estímulos térmicos (prueba de vitalidad pulpar) y de presión (compresión de los tejidos blandos) se realizaron antes y 5 minutos después del procedimiento de bloqueo del nervio alveolar inferior, utilizando tanto la escala analógica visual (VAS) como los cuestionarios de dolor de Mc Gill ( McG). El porcentaje medio de respuesta de los pacientes disminuyó tras el bloqueo del nervio alveolar, según EVA y McG, y fue estadísticamente similar entre hemimandíbulas con y sin canal retromolar (Wilcoxon>0,05); sin embargo, aquellos sin canal retromolar presentaron mayor reducción en la respuesta del paciente en 6 de 9 casos. Por lo tanto, el canal retromolar no es un factor determinante del fracaso del bloqueo del nervio alveolar inferior.


Asunto(s)
Humanos , Tomografía Computarizada de Haz Cónico , Canal Mandibular/efectos de los fármacos , Anestesia , Brasil
11.
Support Care Cancer ; 31(2): 149, 2023 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-36737557

RESUMEN

PURPOSE: To assess radiographic presentation of anatomical structures, bony changes and soft tissue calcifications on panoramic radiographs of oncologic patients under high dose antiresorptive drug therapy (ART) before exposure to dental extraction. METHODS: Panoramic radiographs of 57 patients under ART, taken previously to tooth extraction, and 57 control patients were evaluated by two oral radiologists regarding bone pattern, anatomical structures visibility, estimation of cortical width, mandibular cortical index (MCI), and presence of soft tissue calcifications. Parameters were compared between ART and age- and gender-matched healthy control groups. Bone patterns were further assessed by regions with or without tooth extractions and according to uneventful healing or MRONJ development. All comparisons were made using chi-square test with significance level set at 5%. RESULTS: Mandible and posterior maxilla presented more sclerotic bone patterns in patients under ART, regardless of tooth extraction and MRONJ development status (p < 0.05). Heterogeneous bone pattern was identified in two regions that both were subsequently affected by MRONJ. Anatomical structure visibility and presence of soft tissue calcifications was not different among groups (p > 0.05). ART patients showed significantly more C0 (thickening) and C1 MCI (p < 0.05). CONCLUSION: Sclerotic bone pattern and thicker mandibular cortices may represent a consequence of ART rather than MRONJ specific findings. Prospective studies on larger patient samples radiographically followed-up during the ART treatment are advised, with specific attention to heterogenous trabecular bone pattern as a possible MRONJ predictor.


Asunto(s)
Osteonecrosis de los Maxilares Asociada a Difosfonatos , Conservadores de la Densidad Ósea , Humanos , Osteonecrosis de los Maxilares Asociada a Difosfonatos/diagnóstico por imagen , Osteonecrosis de los Maxilares Asociada a Difosfonatos/etiología , Osteonecrosis de los Maxilares Asociada a Difosfonatos/tratamiento farmacológico , Estudios Prospectivos , Percepción , Conservadores de la Densidad Ósea/uso terapéutico
12.
Oral Dis ; 2023 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-36620873

RESUMEN

OBJECTIVE: To identify local radiographic risk factors for Medication-Related Osteonecrosis of the Jaws (MRONJ) in osteoporotic patients treated with antiresorptive drugs (ARD) and undergoing tooth extraction. MATERIAL AND METHODS: Patients were included in this retrospective, longitudinal, case-control study, if having at least one administration of ARD, underwent tooth extraction(s), and had pre- and post-operative panoramic radiographs. Additionally, a matched control group was selected. Three calibrated, blinded, and independent observers assessed each tooth extraction site. Statistical analysis compared control against study group, and within the latter, sites MRONJ+ and MRONJ-. RESULTS: In total, 120 patients (99 females/21 males) with 354 tooth extractions were included, from which nine patients (7.5%) and eleven tooth extraction sites (3.1%) developed MRONJ. When comparing control with study group, the latter showed significantly more thickened lamina dura, persistence of the alveolar socket, heterogeneous bone patterns, and sequestrum formation. In the study group, MRONJ developed significantly more in males (19%, p = 0.049), smokers (25%, p = 0.008), in the mandible (82%, p = 0.027), when identifying a radiolucent or sclerotic trabecular pattern (p = 0.004) or when extracting teeth with furcation involvement (p < 0.001), root remnants (p = 0.017), or unrestored caries lesions (p = 0.005). CONCLUSIONS: Tooth extraction sites showing radiographic signs of chronic dental infection are prone to MRONJ.

13.
J Hazard Mater ; 446: 130701, 2023 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-36603425

RESUMEN

Serious concerns have recently been raised regarding the association of Fe excess with neurodegenerative diseases in mammals and nutritional and oxidative disorders in plants. Therefore, the current study aimed to understand the physiological changes induced by Fe excess in Pistia stratiotes, a species often employed in phytoremediation studies. P. stratiotes were subjected to five concentrations of Fe: 0.038 (control), 1.0, 3.0, 5.0 and 7.0 mM. Visual symptoms of Fe-toxicity such as bronzing of leaf edges in 5.0 and 7.0 mM-grown plants were observed after 5 days. Nevertheless, no major changes were observed in photosynthesis-related parameters at this time-point. In contrast, plants growing for 10 days in high Fe concentrations showed decreased chlorophyll concentrations and lower net CO2 assimilation rate. Notwithstanding, P. stratiotes accumulated high amounts of Fe, especially in roots (maximum of 10,000 µg g-1 DW) and displayed a robust induction of the enzymatic antioxidant system. In conclusion, we demonstrated that P. stratiotes can be applied to clean up Fe-contaminated water, as the species displays high Fe bioaccumulation, mostly in root apoplasts, and can maintain physiological processes under Fe excess. Our results further revealed that by monitoring visual symptoms, P. stratiotes could be applied for bioindication purposes.


Asunto(s)
Araceae , Hydrocharitaceae , Contaminantes Químicos del Agua , Animales , Hierro , Biodegradación Ambiental , Bioacumulación , Contaminantes Químicos del Agua/toxicidad , Contaminantes Químicos del Agua/análisis , Agua , Mamíferos
14.
Artículo en Inglés | MEDLINE | ID: mdl-36566136

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the influence of the extensive use of a photostimulable phosphor (PSP) receptor on the diagnosis of proximal carious lesions. STUDY DESIGN: Forty posterior teeth were paired and mounted in 20 phantoms. Using a PSP receptor of the Express intraoral system, 1 radiograph of each phantom was acquired, totaling 20 radiographs (group 1). After 400 acquisitions, another radiograph of each phantom was obtained, totaling 20 new radiographs (group 2). This procedure was also done after 800 (group 3), 1,200 (group 4), and 1,600 (group 5) acquisitions, resulting in 100 radiographs. Another 40 radiographs (20 phantoms × 2 groups) were obtained with a second PSP sensor to evaluate the diagnostic replicability of the receptors. All 140 radiographs were assessed independently by 5 examiners for the presence of proximal caries. Area under the receiver operating characteristic curve, sensitivity, and specificity were calculated and compared among the groups by analysis of variance. The Student t test evaluated the diagnostic replicability of the receptors. The significance level was set at 5% (P < .05). RESULTS: The diagnostic outcomes for proximal caries did not differ among the groups (P ≥ .37). The diagnostic values did not differ among the radiographs acquired with the 2 PSP receptors (P ≥ .75). CONCLUSIONS: The diagnosis of proximal carious lesions was not affected by extensive use of the PSP receptor.


Asunto(s)
Caries Dental , Radiografía de Mordida Lateral , Humanos , Caries Dental/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Diente Molar/patología , Sensibilidad y Especificidad
15.
J Oral Rehabil ; 50(1): 1-11, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36271700

RESUMEN

BACKGROUND: There is no established acquisition protocol based on scientific evidence for the acquisition of cone-beam computed tomography (CBCT) exams to evaluate the temporomandibular joint (TMJ). OBJECTIVES: To evaluate the influence of acquisition protocols and jaw positioning on the diagnostic accuracy of TMJ condylar morphological alterations (CMA), dimension, position and excursion. METHODS: Thirty-six TMJs on 18 dry skulls were imaged using a CBCT unit (OP300 Maxio, Instrumentarium, Tuusula, Finland) at two exposure settings (4.5 and 6.3 mA), three voxel resolutions (0.085, 0.125 and 0.280 mm), three jaw positions (concentric, anteriorised and posteriorised) and three jaw excursions (normoexcursion, hyperexcursion and hypoexcursion). The macroscopic anatomy examination and high-resolution CBCT images were used as ground truth for CMA. Twenty-five TMJs had at least one CMA with 11 healthy TMJs serving as controls. Three experienced oral and maxillofacial radiologists evaluated the parasagittal images for the presence of CMA, position and excursion and measured dimensions. The area under the ROC curve, sensitivity and specificity were calculated. Weighted Kappa (α = 0.05) was used to determine intra- and interexaminer reliability and comparisons between dependent variables analysed by Analysis of Variance at an a prior level of significance of 0.05. RESULTS: The agreement of the evaluation of the position and excursion with the reference standard was high, independent of the protocol (range, 0.75-0.91). Various combinations of acquisition protocols and jaw position did not influence the CMA evaluation. Erosion was overdiagnosed in protocols with larger voxel sizes and the detection of osteophytes greater in images with smaller voxel sizes. The anteroposterior dimension was greater in the open jaw position (p < .05). CONCLUSION: CBCT protocols using reduced radiation exposure from the CBCT machine evaluated in this study can be used to assess condylar morphology, dimension, position and excursion, without compromising diagnostic performances for these parameters.


Asunto(s)
Trastornos de la Articulación Temporomandibular , Humanos , Trastornos de la Articulación Temporomandibular/diagnóstico por imagen , Reproducibilidad de los Resultados , Articulación Temporomandibular/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Sensibilidad y Especificidad
16.
Oral Radiol ; 39(1): 53-58, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35218461

RESUMEN

OBJECTIVE: To evaluate whether the automatic exposure compensation in the presence of high-density materials can affect the measurement of alveolar bone level. METHODS: Thirty regions of seven dry skulls and six mandibles were radiographed with and without a high-density material, using two digital radiographic technologies: photostimulable phosphor plate (PSP, Digora Optime) and sensor (CMOS, Digora Toto), totaling 120 images. The distances from the cement-enamel junction to the alveolar bone crest were measured using cone-beam computed tomography (CBCT) images to represent the reference standard. The same measurements of alveolar bone level and the average of the pixel values of the image were evaluated on the radiographs. Paired t test compared the average pixel values and alveolar bone-level measurements between images with and without high-density material. One-way analysis of variance compared the difference between radiographic and CBCT measurements (α = 0.05). RESULTS: The high-density material reduced the pixel values in PSP (p = 0.002) and CMOS (p < 0.001) technologies, demonstrating the AEC functioning in both technologies. There was no difference in bone-level measurements between the images without and with the high-density material for both technologies (p ≥ 0.091), or between the tomographic and radiographic measurements (p ≥ 0.319). CONCLUSION: In the presence of high-density material, the automatic exposure compensation reduces the average pixel values of the images (i.e., images get darker), but does not influence the radiographic measurements of alveolar bone level.


Asunto(s)
Proceso Alveolar , Radiografía Dental Digital , Radiografía Dental Digital/métodos , Proceso Alveolar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico , Mandíbula/diagnóstico por imagen
17.
Artículo en Inglés | MEDLINE | ID: mdl-38632036

RESUMEN

OBJECTIVE: The aim of this study was to present the development of a database (dataset) of panoramic radiographs. STUDY DESIGN: Three radiologists labeled an image set consisting of 936 panoramic radiographs. Labeling includes tooth numbering (including teeth present and missing) and annotation of dental conditions (e.g., caries, dental restoration, residual root, endodontic treatment, implant, fixed prosthesis, incisal wear). The annotation process was performed in a Picture Archive and Communication System software customized for the study purposes using a small bounding box to delimit the entire tooth and items for radiographic diagnosis and a large bounding box to simultaneously delimit the 2 dental arches (maxilla and mandible). A JSON file was generated for each annotation. RESULTS: The database encompassed 23,619 annotations; disagreement between radiologists occurred in 0.7% of the notes. CONCLUSIONS: This work aims to inform researchers about the importance of the labeling process, in addition to providing the scientific community with a bank of labeled images to implement artificial intelligence systems in clinical practice.

18.
Int J Oral Maxillofac Implants ; 37(6): 1202-1209, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36450026

RESUMEN

PURPOSE: To evaluate the influence of the milliamperage and artifact reduction (AR) tool on the diagnosis of buccal and lingual peri-implant dehiscences related to titanium-zirconia (Ti-Zr) and zirconia (Zr) implants using CBCT images. MATERIALS AND METHODS: Ti-Zr and Zr implants were alternately inserted in 20 sites in the posterior region of three human mandibles that presented intact cortical (control) bones or simulated buccal and/or lingual peri-implant dehiscences. CBCT images were acquired with an OP300 Maxio unit, varied milliamperage (5 and 8 mA), and the use of AR tool. Three oral radiologists assessed the presence of dehiscences using a 5-point scale. The area under the receiver operator characteristic curve (Az), sensitivity, and specificity of each group (control and dehiscence) were obtained and compared using multiway ANOVA (α = .05). RESULTS: The milliamperage and the AR tool did not influence the diagnosis of dehiscences, and there were no differences between the buccal and lingual cortices (P > .05). However, Zr implants showed a higher sensitivity (0.67 to 0.89) and lower specificity (0.26 to 0.44) than Ti-Zr implants (0.19 to 0.44 and 0.93 to 1.00, respectively; P < .05). Az values did not differ between the implant types (P > .05). CONCLUSIONS: Dehiscences were more detectable when related to Zr implants, while the absence of dehiscences was more correctly visualized adjacent to Ti-Zr implants. The use of varied milliamperages and the AR tool did not affect the diagnosis of peri-implant dehiscences, regardless of the involved cortical (buccal or lingual) bones.


Asunto(s)
Implantes Dentales , Tomografía Computarizada de Haz Cónico Espiral , Humanos , Artefactos , Implantes Dentales/efectos adversos , Titanio
19.
Phys Rev E ; 106(1-1): 014136, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35974542

RESUMEN

We investigate the stochastic susceptible-infected-recovered (SIR) model of infectious disease dynamics in the Fock-space approach. In contrast to conventional SIR models based on ordinary differential equations for the subpopulation sizes of S, I, and R individuals, the stochastic SIR model is driven by a master equation governing the transition probabilities among the system's states defined by SIR occupation numbers. In the Fock-space approach the master equation is recast in the form of a real-valued Schrödinger-type equation with a second quantization Hamiltonian-like operator describing the infection and recovery processes. We find exact analytic expressions for the Hamiltonian eigenvalues for any population size N. We present small- and large-N results for the average numbers of SIR individuals and basic reproduction number. For small N we also obtain the probability distributions of SIR states, epidemic sizes and durations, which cannot be found from deterministic SIR models. Our Fock-space approach to stochastic SIR models introduces a powerful set of tools to calculate central quantities of epidemic processes, especially for relatively small populations where statistical fluctuations not captured by conventional deterministic SIR models play a crucial role.

20.
Odovtos (En línea) ; 24(2)ago. 2022.
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1386600

RESUMEN

Abstract The aim of this study was to evaluate the observers diagnostic performance in panoramic radiography using monitor, tablet, X-ray image view box, and against window daylight as a visualization method in different diagnostic tasks. Thirty panoramic radiography were assessed by three calibrated observers for each visualization method, in standardized light conditions, concerning dental caries, widened periodontal ligament space, and periapical bone defects from the four first molars; mucosal thickening and retention cysts in maxillary sinus; and stylo-hyoid ligament calcification and atheroma. A five-point confidence scale was used. The standard-reference was performed by two experienced observers. Diagnostic values using window light were significantly lower for caries and periapical bone defect and retention cyst, stylo-hyoid ligament calcification detection (p<0.05). For atheroma detection, X-ray image view box, tablet, and widow light had lower accuracy than the evaluation on the monitor (p<0.05). Observers diagnostic performances are worsened using window light as an evaluation method for panoramic radiography for dental, sinus, and calcification disorders, while the monitor was the most reliable method.


Resumen El objetivo de este estudio fue evaluar el desempeño diagnóstico de los observadores en la radiografía panorámica utilizando monitor, tablet, caja de visualización de imágenes de rayos X y contra la luz del día de la ventana como método de visualización en diferentes tareas de diagnóstico. Treinta radiografías panorámicas fueron evaluadas por tres observadores calibrados para cada método de visualización, en condiciones de luz estandarizadas, con respecto a caries dental, espacio del ligamento periodontal ensanchado y defectos óseos periapicales de los cuatro primeros molares; engrosamiento de la mucosa y quistes de retención en el seno maxilar; y calcificación y ateroma del ligamento estilohioideo. Se utilizó una escala de confianza de cinco puntos. La referencia estándar fue realizada por dos observadores experimentados. Los valores diagnósticos con luz de ventana fueron significativamente menores para caries y defecto óseo periapical y quiste de retención, detección de calcificación del ligamento estilohioideo (p <0.05). Para la detección de ateroma, la caja de visualización de imágenes de rayos X, el tablet y la luz de viuda tuvieron una precisión menor que la evaluación en el monitor (p <0.05). El rendimiento diagnóstico del observador empeora al utilizar la luz de la ventana como método de evaluación de la radiografía panorámica para los trastornos dentales, de los senos nasales y de la calcificación, mientras que el monitor fue el método más fiable.


Asunto(s)
Radiografía Panorámica/instrumentación , Diagnóstico Bucal , Procesamiento de Imagen Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...